MDU-102
MDU-102 is intended to multiply NMEA 0183 signal (versions 1,2) or other signals (RS-232, RS-422/485 serial transfer, 1 or 2 supplies) and is provided for a checksum option of CH1 data
- Supply Voltage 10-36VDC/18-36VDC
- Power Consumption no more than 3W
- Galvanic Isolation (mains supply)
- Loop back protection
- Over voltage protection (fuse 1A)
- 2 inputs (CH1, CH2)
- Supported Interfaces RS-232, RS-422/485
- Max data receive rate 115200 bps
- Optical isolation
- 8 (2 x 4) outputs
- 2 (A and B) output group’s number
- Optical isolation 4 non-isolated, 4 isolated